FLOC-P Waste-Slurry FlocculantNPT-FLOC-P
A high-efficiency anionic polyacrylamide flocculant for waste-slurry separation — clear water for reuse, and a dry cake for haul-away disposal.
Product Overview
One-liner: Solid-liquid separation, clear water back to use, A high-efficiency anionic polyacrylamide flocculant for waste-slurry separation — clear water for reuse, and a dry cake for haul-away disposal.
FLOC-P is a high-molecular-weight anionic flocculant. It bridges fine particles into large fast-settling flocs, separating cuttings from water. The clear layer is low in turbidity and reusable; the low-moisture cake can be loaded and hauled for dry stacking, cutting disposal volumes and cost.
Fast separation
Large flocs settle quickly for high throughput.
Clear water
Low-turbidity supernatant that can be reused or discharged within limits.
Dry cake
Low-moisture cake loads and hauls away without dripping.
Applicable Strata / Scenarios
| Strata type | Typical scenario | Recommended ratio | Expected effect |
|---|---|---|---|
| Shield waste slurry | Solid-liquid separation | 20–50 g/m³ | Effluent SS in spec |
| Pile waste slurry | Mud-water separation | 30–60 g/m³ | Low cake moisture |
| Seawater waste slurry | Salt-tolerant flocculation | 50–100 g/m³ | Works at high salinity |
| Circulating water | Reuse treatment | 10–30 g/m³ | Lower turbidity |
Technical Data Sheet
Quantified core indices for product selection and tender comparison; a test report ships with every batch.
| Test item | Specification | Test method |
|---|---|---|
| Appearance | White granules | Visual |
| Molecular weight | 10–15 million | Viscometry |
| Hydrolysis degree | 25%–35% | Titration |
| Active content | ≥ 88.0% | Oven drying |
| Charge type | Anionic | Colloid titration |
| Dissolution time | ≤ 60 min | Stirring observation |
How to Use / Mix Design
| Step | Key points | Reference dosage |
|---|---|---|
| Stock solution | Sprinkle slowly into stirred water to make a 0.1%–0.3% solution | 0.1%–0.3% |
| Dose | Meter by waste-slurry volume | 20–100 g/m³ |
| Mix | Mix in-line or with a stirrer | — |
| Monitor | Check supernatant turbidity and pH | Once per batch |
Related Solutions
Related Cases
Tell us your strata conditions —
get tailored selection advice
Share your strata, borehole diameter and schedule; engineers will reply with mix advice, quantity estimates and lead time. Your information is used only for this enquiry.